Verified Supplier | Shanghai Medic Indus...

Shanghai Medic Industry Co., Ltd.

China (Mainland) | Trading Company | Contact Details
Established 2005
Response Rate
Company Feedback

Quick Details

  • Type: Pathological Analysis Equipments
  • Brand Name: ---
  • Place of Origin: China (Mainland)
  • Model Number: Protable Patient Monitor

Packaging & Delivery

Packaging Details: carton
Delivery Detail: within 15 days
10.4 inch high brightness colorful TFT LCD
Simultaneous display of 7 channel waveform by one screen
Dual NIBP with over pressure protection
Analysis of real time ST segment and arrhythmia
Standard parameter of ECG, NIBP, RESP, SPO2, 1-TEMP, PR, drug dose calculation , OXYCRG
   Optional configuration: 12 lead ECG,  2-TEMP, IBP(single/dual), ETCO2(side stream/main stgream), 
       built in thermal printer and CO
Maximum 120 hour graphic and tabular trend with data storage
Standard RJ-45 socket to support networking capacity of maximum 66 beds and compatibility with HIS
Digital SPO2 enables effective examination in case of active patient and low infusion as well 
      interference caused by electrosurgical unit
Compact and portable design allows uninterrupted operation with its built in rechargeable battery
Technical Specifications
Size and Weight

Name of the monitor

Multi-parameter Monitor





System output

Display type

12.1″LCD color display screen, with a resolution of 800×600

Interface with central unit

Network port

Power supply

Power Voltage

AC 100V~240V 50/60Hz

Power Input




Safety Level

Class I , Type CF



Rechargeable Lead acid cell, 12V/3.2AH

Charge time

≤6 hours

Working hours when charged fully

≥30min when using normally


Ambient Temperature

Working 0~+40ºC
Transportation and storage –20~+50ºC

Relative humidity

Working ≤85%
Transportation and storage ≤93%

Atmospheric pressure

Working 860~1060 hPa
Transportation and storage 500~1060 hPa


Lead Mode

  1. 5-leads ECG input
  2. 3-leads ECG input
  3. 10-leads ECG input

Lead selection

  1. I, II, III, aVR, aVL, aVF, V-
  2. I, II, III
  3. I, II, III, aVR, aVL, aVF, V1~V6


2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV

Input impedance

≥5.0 Mohm (d.c. ~ 60 Hz)


DIAG ≥85dB
MON ≥105dB
OPS ≥105dB

Frequency response

DIAG 0.05~75Hz
MON 0.5~25Hz
OPS 1~15Hz

Electrode offset potential

±300 mV d.c. → ±600mV d.c.

Leakage Current

<10 uA

ECG signal range

±6.0 mV

Baseline recovery

<5 s After Defi. (MON or OPS mode)


Breakdown Voltage 4000VAC 50Hz/60Hz

Indication of electrode separation


Sweep speed

12.5mm/s, 25mm/s, 50mm/s

HR Measuring and Alarm


10~300 bpm

Refreshing time

Per pulse


1 bpm


±1% or ±1 bpm, whichever is greater

Alarm range

10~300 bpm, continuously adjustable between high limit and low limit

Alarm indication

Sound and light alarming

Last Update Time:2013-12-27
Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview


Transaction Details

This supplier has completedtransactions with buyers from .

Buyer’s Country
Transaction Value
Transaction Date
Email to this supplier
Verified Supplier - Shanghai Medic Industry Co., Ltd.
China (Mainland) | Trading Company | Contact Details
Established 2005
Response Rate
Company Feedback